Иконка для Cover Depth Electrical 1.1

Cover Depth Electrical (v. 1.1)

Intineo опубликовал приложение 2011-04-18
(обновлено 2011-04-18)

NEC and CEC (Canadian Electrical Code) Cover Requirements for
Cables, Conductors and Raceways.

References Pertinent data from NEC Tables 300.5 and 300.50,
as well as CEC Table 53 and Rule 12-012.

Helpful aid to determining burial depth for electrical conductors in the U.S. or Canada.

Keywords: Electrician, Cover Requirements, Burial Depth

Бесплатно
Иконка для Conduit Runner Pro 4.1.1

Conduit Runner Pro (v. 4.1.1)

Intineo опубликовал приложение 2011-04-02
(обновлено 2012-08-21)

March Madness - >50% Off

SUBSET OF Electrical Wiring Pro app -- IF YOU HAVE ELECTRICAL WIRING PRO, YOU HAVE THIS FUNCTIONALITY AS OF VERSION 5.1

Conduit Bends, Fill and other calculations:
BENDS:
-Offsets, inc rolling
-Parallel Runs
-3-bend Saddle
-Corner obstacles
  o Round or Rectangle
-Segment Bending

FILL:
-Minimum Size Conduit for Wires, Cables, Custom
-% Fill
-# Wires/Conduit (AWG, Trade Sizes)
-Conduit Info
-Wire Info

OTHER (per NEC 2008):
- Length converter
- Minimum Radius for Conduit/Tubing by size
- Required Cover Depth
- Pull Box Sizing
- AWG-Metric wire converter (not NEC)

-Fractions (1/2-1/16 precision)
-Decimal (0-4 places)

Length Converter:
Enter any of meters, inches-fraction, inches-decimal, feet-inches-fraction or feet-inches-decimal and the other 4 quantities will be displayed.

Keywords: Electrical, Electrician, Conduit Bend

US$0.99
Иконка для Canadian Wiring Lite 3.0

Canadian Wiring Lite (v. 3.0)

Intineo опубликовал приложение 2011-02-09
(обновлено 2012-05-24)

Electrical Wiring per the 2009 Canadian Electrical Code.

Free application, part of the Intineo Wiring Series.

Ampacity & Wire Sizing
- Determine ampacity for a given wire per Tables 1-4
- Given ampacity required, determine wire size needed per
Tables 1-4
- Grounding Conductor Sizing
- Bonding Conductor Sizing

Conduit Bends
- Offsets
- Three-bend saddles

Transformers
- Basic Sizing
- Fault current and power
- Delta Coil current and voltage
- Wye configuration current and voltage

Extras!
- Pire Wheel - put in any two of Power, Current, Voltage and
Resistance, and Pire wheel determines the other two
- Burial Depth required per Table 53 and Rule 12-012
- AWG-Metric wire size comparison
- Temperature conversion for 8 different scales
- Parallel Loads (any number)

We hope you find the app useful!


Note to users of "Electrical Wiring Pro" -- in the future,
all CEC-related apps will be removed from "Electrical Wiring Pro" and put in the "Canadian Wiring xxx" series.

Бесплатно
Иконка для AWG Metric Wire Converter 1.1

AWG Metric Wire Converter (v. 1.1)

Intineo опубликовал приложение 2010-12-11
(обновлено 2010-12-11)

For Electrical Designers, Electricians, and others working with electrical wire.

Helps convert between AWG & Metric Wire Sizes by providing
size information to make a choice between the next smallest or
largest wire size in the other system.

Includes both solid and stranded, standard wire sizes from 0.5mm^2 to 2000 kcmil.

Бесплатно
Иконка для Conduit Bend Lite 1.5

Conduit Bend Lite (v. 1.5)

Intineo опубликовал приложение 2010-11-05
(обновлено 2011-07-30)

EZ Conduit Bend calculator for offset and 3-bend saddles.


For Electricians bending conduit, or others doing Electrical work.

No ads.

Бесплатно
Иконка для Pull Box Helper 1.1

Pull Box Helper (v. 1.1)

Intineo опубликовал приложение 2010-10-21
(обновлено 2011-06-26)

Helps size height, width and depth of pull/junction boxes and conduit bodies for wire sizes 4 AWG and larger.

Based on NEC 2008 314.28.

Electrical Wiring Pull Boxes, Gutters, Junction Boxes, Condulets, Conduit Bodies.

Free Beta/Draft.  Send feedback to developer support@intineo.com

Бесплатно
Иконка для 3 Phase - Beta 1.1

3 Phase - Beta (v. 1.1)

Intineo опубликовал приложение 2010-09-09
(обновлено 2011-03-25)

3 Phase current, voltage and
KVA.

Delta or Wye configurations.

Beta - email suggestions or issues to support@intineo.com

Бесплатно
Иконка для MotorMan 1.2

MotorMan (v. 1.2)

Intineo опубликовал приложение 2010-09-01
(обновлено 2011-03-07)

NEMA Standard Motor Dimensions

If you don't know what a T-Frame is, this may not be the app for you.

Input Frame Size or HP+RPM+Era,
output is dimensions.

Also tables of Open and Enclosed 3-phase frame sizes.

Click on motor picture to get alternate view of graphic.

For my friends who work on motors...

Бесплатно
Иконка для Pire Wheel 2.0.1

Pire Wheel (v. 2.0.1)

Intineo опубликовал приложение 2010-08-09
(обновлено 2011-01-10)

Subset (1/21 apps) of Electrical Wiring Pro

Electrical Pire Wheel

Interactive graphic with any two of:

P - Power
I - Amps
R - Ohms
E - Volts

to find the other two, using the formulas taught in basic electrical classes.

Calculator for Electrician's using Pire Wheel.

Бесплатно
Иконка для Electrical Wiring Pro 4.5

Electrical Wiring Pro (v. 4.5)

Intineo опубликовал приложение 2010-07-26
(обновлено 2011-10-08)

SALE PRICE >75% OFF!!!

Over 2 dozen Useful Electrical Tools

Wide Coverage of National Electrical Code 2005, 2008 and
2011.

NEC 2011 and Canadian Electrical Code, 2009 functionality in process.

o Ampacity / Wire Size (AWG only)
- Wire Size -> Ampacity
- Ampacity Needed -> Wire Size
- Voltage Drop -> Wire Size
- Dwelling Service Size
- GEC Size
- EGC Size
- New Ampacity section includes
   o Improved user interface,
   o Canadian Electrical Code Compatibility
   o NEC 2005, 2008 and 2011 (the updates are accounted for by the app)
   o > 700 locations with Ambient Temps


o Boxes / Cover
- Box Size from Wires / Devices
- Box Size from Cables / Devices
- Standard Box and Typical Plaster Ring INfo
- Pull Box Sizing


o Conduit
- Conduit Bends (basic offsets & saddles - subset of what is in "Conduit Runner Pro")
- Conduit Fill
  - Wires -> Conduit Size Needed
  - Wires/Conduit -> % full
  - Maximum Wires/Conduit
  - Conduit Size Information
  - Wire Size Information

o Voltage Drop
- Required voltage or % drop -> Wire Size
- Voltage Drop Calculation
- Maximum Length for voltage or % drop
- Maximum Load for voltage or % drop
- Impedance given wire length


o Motors
- FLC, Wire, Breaker, Heater, Starter, Conduit etc. Sizing
- Locked Rotor Current
- KVAR Capacitor Correction
- NEMA Motor Dimensions

oTransformers
- Basic Transformer Sizing
- Transformer Faults
- Delta-Wye configuration

o Other
- Pire Wheel / Ohms Law
- AWG-Metric wire size comparison
- Cover Depth (CEC 2009, NEC 2005, 2008, 2011
- Temperature Converion for 8 different scales

o Configurable
- NEC 2005, 2008, 2011 or Canadian Electrical Code 2009
   (currently limited to cover depth only)
- Limited selection fraction for conduit bends (full selection in Conduit Runner Pro)


If you would like to report bugs or suggestions, please send them to:
support aatt intineo dot com
rather than use the comment mechanism so we can respond
directly -- thank you.

US$0.99
Страница:  1   2    »